Cement Header
Cement

Al Saeed Low Heat Portland Cement

El Saeed cement is a low heat of hydration cement; It is the result from crushing a dry mix made of clinker and gypsum.


The reaction between cement and water generates heat of hydration not more than 250 Kj/Kg after 7 days.


Uses and applications

It can be used in all types of constructions.
It is suitable for concrete elements of large cross sections (mass concrete).
Suitable to be used in the hot weather.


Advantages

  • 1. It gives high final compressive strength (28 days).
  • 2. It gives more workability for the concrete.
  • 3. It reduces concretes cracks.
  • 4. Suitable to be used in hot weather.

Standard specifications:

ES 2009/ 1 4756


Chemical properties:

Average Results of El Saeed ES 2009/ 1 4756
C3S 42 - 44 (Maximum) 45 % (by weight)
Loss of ignition 1.6 - 1.9 (Maximum) 4 % (by weight)
Insoluble residues 0.4 - 0.7 (Maximum) 1.5 % (by weight)
Chlorides Content 0.02 – 0.04 (Maximum) 53% (by weight

Physical and Mechanical properties:

Average results of El Saeed ES 2009/ 1 4756
Surface area Cm2/gm (Blaine Method) 3000 - 3100 No less than 2800
Setting time
Initial setting time 130 - 180 Not less than 45 min.
Final setting time 190 - 250 N.A.
Hydration KJ/Kg after 7 days 210 - 220 Not more than 250Kj/Kg
Soundness (Le Chatelier) 0.0 - 1.0 Not more than 10 mm

Compression strength N/mm2:

Average results of Al Saeed ES 2009/ 1 4756
After 2 days 16 - 20 N.A.
After 7 days 22 - 27 Not less than 17.5 N/mm2
After 28 days 35 - 40 Not less than 32.5 N/mm2 & Not more than 52.5 N/mm2

Comparison between the average results of El Saeed and ES.2149/2005.

Al Saeed

Packing:

  • Bags: 50 Kg/bag
  • Jumbo plastic bags: 500 Kg/bag, 1000 Kg/bag, 1500 Kg/bag
  • It is also available in bulk.

Storage:

It is recommended to follow the coming instructions:

  • Storage should be done in a dry place and away from ground moisture.
  • It is preferable to store it on wooden bases.
  • Cement should be covered to avoid the rain.
  • It is recommended not to pile up any more than ten bags, some on others.

Shelf time

It is recommended to retest the cement after 6 weeks from the production date.


Safety recommendations

It is recommended to follow the coming instructions:

  • Avoid the contact of the cement with the eyes and the skin since it may cause allergic reaction.
  • Use gloves and glasses to protect hands and eyes in case of spray applications, or manual mixings.

How to clean the cement remains of the used tools

  • Before setting: by using clean water.
  • After setting: by using mechanical methods.

Environment concept

It is advised and recommended to follow local environmental instructions.

Al Saeed Cement