A1 Mortar Cement for all finishing and plastering works
Dry Mortar cement
- Ideal workability
- No wastage
- Final plastering surface without any cracks
- The best workability with the best cohesion (MC 22.5X)
It has a wide range of applications for finishing works:
- External and internal plastering
- Floor and Ceramic tiling
- Electric & Plumbing Installations
Don’t use this product in reinforced concrete & foundations works
- Egyptian Standard Specifications (ES. 8498-1/2022) (MC 22.5X)
- European Standard Specifications masonry cement (EN 413-1 /2011)
Item |
|
Spec. Limit |
Test Result |
SiO2 |
% |
---- |
20.37 |
Al2O3 |
% |
---- |
4.97 |
Fe2O3 |
% |
---- |
6.43 |
CaO |
% |
---- |
48.53 |
MgO |
% |
---- |
1.77 |
SO3 |
% |
3.5 max. |
2.05 |
Na2O |
% |
---- |
0.81 |
K2O |
% |
---- |
0.76 |
Cl |
% |
0.1 max. |
0.04 |
Item |
Unit |
Spec. limits |
results |
Fineness, Blaine |
cm2 /gm |
---- |
5004 |
Water Retention |
% |
75.0 Min |
29.00 |
Residue on a - 90 um |
% |
15% Max |
14.2 |
Initial Setting time |
Minutes |
60.0 min. |
150 |
Final Setting time |
Minutes |
---- |
205 |
Le chatelier expansion |
mm |
10.0 max. |
0.06
|
Air content,max% |
% |
6 max% |
5.40 |
Compressive Strength |
Mpa(N/mm2) |
---- |
---- |
2 days |
---- |
10.25 |
|
7 days |
10 min |
15.8 |
|
28 days |
22.5 min., 42.5 max. |
26.35 |
It is recommended to follow local environmental instructions, and not throwing it into water canals, sewages or agricultural soils
It is not poisonous according to the international specs for health and safety.
It is recommended to follow the coming instructions:
- Storage should be done in a dry place and away from moisture ground.
- It is preferable to store it on wooden bases.
- Cement should be covered to avoid the rain.
- It is recommended not to pile up any more than eight bags, some on others.
- Eye Contact: Flush the eyes with plenty of water and seek medical doctor advice
- Skin Contact: Wash the skin with natural soap and water, use moisturizing cream, then consult medical doctor.
- Ingestion: Do not vomit or drink large amount of water and seek medical doctor advice.
- Inhalation: Move person to fresh air area, if the person is not breathing, make CPR (artificial respiration), and if there is difficulty in breathing, provide person with oxygen and seek medical doctor.
- Bags: 50 Kg/bag
- Jumbo plastic bags: 500 Kg/bag, 1000 Kg/bag, 1500 Kg/bag
- Available in bulk
- Before setting: By using clean water
- After setting: By using mechanical tools.
It is recommended to retest the cement after 6 weeks since the production date
For best results, it is recommended to do the following:
- Sand shall be added to the mix according to the applications type.
- Consider sand washing before the mixing process.
- Ensure that the sand is free of the clay and organic impurities
- The dry mixing process with sand must be done well to ensure the homogeneity of the dry ingredients before adding water.
- It is preferable to use clean water free of salt, and in general it is possible to use water that human can drink.
- It is preferable to use the cement before the end of half of the validity period, in general it is preferable to test the cement after the middle of its validity period
It is recommended to follow the coming instructions:
- Avoid the contact of the cement with the eyes and the skin since it may cause allergic reaction.
- Breathing cement could cause allergy in the nose, throat or lungs and the continuity of breathing could cause lung damage
- Use gloves and glasses to protect hands and eyes in case of spray applications, or manual mixings.
Our technical support team will help you by calling us on this number:
+20 105 004 4781